ElpasoLight™
ElpasoLight™ CLYC is a new material based on Ce-doped double Perovskite structure and is a an excellent dual-mode neutron-gamma radiation detector. With a gamma energy resolution near 4%, a high cross-section for thermal neutrons, and excellent pulse shape discrimination (PSD) of 2.6, it is a promising replacement for medium resolution gamma-ray detectors and 3He tubes. These scintillators can also be enriched with 6Li or 7Li for adjusting thermal-neutron cross section.
- Sizes of ElpasoLight crystals up to d76x152mm3 (d3”x6”) are commercially available (larger sizes can be manufactured upon request)
- Medium light output 20,000 ph/MeV of gamma energy and 70,000 ph/neutron
- Energy resolution near 4% at 662 keV
- High cross-section for thermal neutrons
- Available as packed crystals, with standard PMTs or with SiPM readouts
- Custom configurations available upon request
Request a quote
Out of stock

Specification
Item |
Crystal shape |
Crystal size, mm |
Vol.,cc |
Readout |
Additional Information |
|
|
|
|
None |
|
EL-25×2 |
cylinder |
d25.4×2.0 |
1.0 |
Quartz window |
0.1mm Be window for low energy X-rays. |
EL-51x51x13 |
cuboid |
50.8×50.8×12.7 |
32.8 |
Quartz window |
Optical window on the 50.8×50.8mm2 face. |
EL-25×25 |
cylinder |
d25.4×25.4 |
12.9 |
Quartz window |
Encapsulated in 1mm thick Al canister with a quartz window. |
EL-38×38 |
cylinder |
d38.1×38.1 |
43.4 |
Quartz window |
EL-51×51 |
cylinder |
d50.8×50.8 |
103.0 |
Quartz window |
EL-63×63 |
cylinder |
d63.5×63.5 |
201.0 |
Quartz window |
Encapsulated in 1.5mm thick Al canister with a quartz window. |
EL-76×76 |
cylinder |
d76.2×76.2 |
347.5 |
Quartz window |
|
|
|
|
|
SiPM |
|
EL-6x6c-SiPM |
cube |
6.0×6.0x6.0 |
0.2 |
6mm SiPM |
Fast and standard outputs. |
EL-6x12c-SiPM |
cuboid |
6.0×6.0x12.0 |
0.4 |
6mm SiPM |
Fast and standard outputs. |
EL-13c-SiPM-T |
cube |
12.7×12.7×12.7 |
2 |
2×2 6mm SiPMs |
Fast and standard outputs. Integrated temperature sensor. |
EL-14x2c-SiPM-T |
cuboid |
14.0×14.0x2.0 |
0.4 |
2×2 6mm SiPMs |
0.1mm Be window for low energy X-rays Fast and standard outputs. Integrated temperature sensor. |
EL-14x25c-SiPM-T |
cuboid |
14.0×14.0x25.4 |
5 |
2×2 6mm SiPMs |
Fast and standard outputs. Integrated temperature sensor. |
EL-14x51c-SiPM-T |
cuboid |
14.0×14.0x50.8 |
10 |
2×2 6mm SiPMs |
EL-14x102c-SiPM-T |
cuboid |
14.0×14.0x101.6 |
20 |
Upon request |
Multiple readout configurations available. |
EL-51x51x13-SiPM-T |
cuboid |
50.8×50.8×12.7 |
32.8 |
Upon request |
|
|
|
|
|
PMT |
|
EL-25×25-R3998 |
cylinder |
d25.4×25.4 |
12.9 |
R3998 |
Encapsulated with magnetic shielding and moisture barrier. |
EL-25×25-R11265 |
cylinder |
d25.4×25.4 |
12.9 |
R11265U |
Low profile rugged metal case PMT. |
EL-25×51-R11265 |
cylinder |
d25.4×50.8 |
25.8 |
R11265U |
EL-25×102-R11265 |
cylinder |
d25.4×101.6 |
51.6 |
R11265U |
|
EL-38×25-R6231 |
cylinder |
d38.1×25.4 |
29 |
R6231 |
Encapsulated with magnetic shielding and moisture barrier. |
EL-38×38-R6231 |
cylinder |
d38.1×38.1 |
43.4 |
R6231 |
EL-38×51-R6231 |
cylinder |
d38.1×50.8 |
57.9 |
R6231 |
|
EL-51×25-R6231 |
cylinder |
d50.8×25.4 |
51.5 |
R6231 |
Encapsulated with magnetic shielding and moisture barrier. |
EL-51×38-R6231 |
cylinder |
d50.8×38.1 |
77.2 |
R6231 |
EL-51×51-R6231 |
cylinder |
d50.8×50.8 |
103 |
R6231 |
|
|
|
|
|
|
EL-64×64-R6233 |
cylinder |
d63.5×63.5 |
201.0 |
R6233 |
Encapsulated with magnetic shielding and moisture barrier. |
EL-64×160-R6233 |
cylinder |
d63.5×160.0 |
506.7 |
R6233 |
|
|
|
|
|
|
EL-76×76-R10233 |
cylinder |
d76.2×76.2 |
347.5 |
R10233 |
Encapsulated with magnetic shielding and moisture barrier. |
EL-76×152-R10233 |
cylinder |
d76.2×152.4 |
695.0 |
R10233 |
Design and specifications are subject to change without notice.
For details please refer to the datasheet.
Downloads