Specification

AT1120ME
Detection Unit (DU) BDKG-05S
Processing Unit (PU5) РU5 is a hand-held PC (HPC) with integrated detection module
Detectors Scintillation SrI2(Eu) Ø38×38 mm (DU)
Geiger-Muller counter tube (PU5)
Energy range 20 keV – 3 MeV (DU)
60 keV – 3 MeV (PU5)
Detectable activity of 137Cs source, located at the distance of 20 cm in a time not longer than 2 s (40±4) kBq
Typical resolution at 662 keV (137Cs) 3.2%
Measurement range of ambient dose equivalent rate 0.03 – 150 µSv/h (DU)
1 µSv/h – 100 mSv/h (PU5)
Limits of tolerable intrinsic relative error ±20%
Typical sensitivity to 137Cs gamma radiation 850 cps/(µSv·h-1) (DU)
Energy dependence relative to 662 keV (137Cs) ±20% (50 keV to 3 MeV) (DU)
-25% to +35% (60 keV to 3 MeV) (PU5)
Response time for dose rate change from 0.1 to 1 µSv/h ≤2 s (DU)
Protection class IР67
Overall dimensions, weight (assembled with handle) 320х180х160 mm, 1.85 kg

Design and specifications are subject to change without notice.
For details please refer to the datasheet.