Specification
| Pedestrian Radiation Monitors | |
| False alarm rate | ≤1 for 8 h of continuous operation | 
| PC interface | RS 485 | 
| Continuous battery operation time | ≥6 h | 
| Protection class | IР65 | 
| Overall dimensions, weight | depending on configuration | 
| Gamma radiation detection unit | BDKG-19 | BDKG-35 | BDRM-05 | 
| Scintillation detector | NaI(Tl) Ø63×160 mm | Plastic Ø70х150 mm | Plastic 1000х100х50 mm | 
| Energy range | 50 keV – 3 MeV | 20 keV – 3 MeV | 50 keV – 3 MeV | 
| Typical sensitivity, cps/(µSv·h-1) | 32500 [241Am]
 4900 [137Cs] 2800 [60Co]  | 
10000 [241Am]
 3600 [137Cs] 2300 [60Co]  | 
60000 [241Am]
 31500 [137Cs] 16500 [60Co]  | 
| Minimal detectable gamma radiation dose rate level above background value 0.1 µSv/h in a period not longer than 2 s | 0.03 µSv/h | 0.04 µSv/h | 0.01 µSv/h | 
| Detection threshold for unshielded source at 1 m height under natural radiation background conditions not more than 0.1 µSv/h
 (Distance to source 1 m, source travel speed 5 km/h, probability of source detection 80 % under confidence level Р=0.95)  | 
|||
| One detection unit | 430 kBq [241Am]
 220 kBq [137Cs] 100 kBq [60Co]  | 
1180 kBq [241Am]
 230 kBq [137Cs] 100 kBq [60Co]  | 
800 kBq [241Am]
 110 kBq [137Cs] 60 kBq [60Co]  | 
| Two detection units | 320 kBq [241Am]
 160 kBq [137Cs] 70 kBq [60Co]  | 
860 kBq [241Am]
 170 kBq [137Cs] 70 kBq [60Co]  | 
580 kBq [241Am]
 80 kBq [137Cs] 40 kBq [60Co]  | 
| Neutron radiation detection unit | BDKN-01 | BDKN-05 | 
| Detector | He-3 proportional counter in polyethylene moderator | Two He-3 proportional counters in polyethylene moderator | 
| Energy range | 0.025 eV – 14 MeV | 0.025 eV – 14 MeV | 
| Typical sensitivity to source radiation at the distance of 1 m, cps/(neutron·s-1·cm-2) | 1.3 [252Cf] | 20 [252Cf] | 
| Source detection threshold at 1 m height
 (Distance to source 1 m, source travel speed 5 km/h, probability of source detection 80% under confidence level Р=0.95)  | 
||
| One detection unit | 2.2·105 neutron/s [252Cf] | 2.3·104 neutron/s [252Cf] | 
| Two detection units | – | 1.6·104 neutron/s [252Cf] | 